Effect of the gonadal integrity and the gender on responses of bone crestal levels in dogs with two dental prosthetic abutment types

Authors

  • Gilberto Valenzuela Vásquez UNIVERSIDAD AUTONOMA DE BAJA CALIFORNIA

DOI:

https://doi.org/10.21640/ns.v7i15.274

Keywords:

bone loss, neutered, dogs, dental implant, platform switching

Abstract

Fourteen adult mongrel dogs (5 intact and 9 neutered) comprising seven males and seven females were used to evaluate change in levels of alveolar crestal bone after implanting two types of dental abutments. Implants were surgically placed in both mandibular fourth premolar zones and restored with conventional (CONV) and platform switching (PFS) abutments. Both abutments were evaluated in each dog. The study lasted 180 days; restoration was performed at Day 60 postsurgical-placed implants and alveolar crestal bone levels was evaluated on Days 0, 30, 60, and 90 post-restoration (cemented crown) through indirect measurement using a digital X-ray sensor. Experimental data were analysed using a completely randomized design: the experimental unit was the dog (random effect), the treatment was the abutment type (fixed effect), and crestal bone level of each implant side (mesial and distal) was the observation. In addition, the gonadal integrity (intact and neutered) and the gender (male and female) were included in the statistical analysis to evaluate their role on the magnitude of changes (interactions) on alveolar crestal bone levels. The average of crestal bone loss was 0.400 ± 0.186 mm. In general, dogs with CONV had a greater (27.3%, P < 0.05) crestal bone loss than dogs with PFS. Intact dogs that received PFS had minor (P < .01) bone loss than dogs receiving CONV, but in neutered dogs, abutment type had no effect (P = 0.98) on crestal bone loss level; therefore, an interaction (P < 0.01) between type of abutment and gonadal conditions was detected. There was no interaction (P > 0.77) between gender and abutment type. Similarly, as a sole factor of variation, gender had no effect (P = 0.26) on crestal bone level responses to abutment type (-0.401 vs -0.385 mm for males and females, respectively). Regardless of the type of abutment, males and females had a similar (P = .65) crestal bone loss (-0.405 vs. -0.393), while neutered dogs showed a greater (30.8%, P < 0.01) crestal bone loss compared with intact dogs. In conclusion, dogs with PFS showed less crestal bone loss than CONV; however, regardless of gender, this response only was maintained in intact dogs; therefore the gonadal condition has an effect on the magnitude of changes of the alveolar crestal bone levels in their response to abutment type in dogs with dental implants.

Downloads

Download data is not yet available.

Author Biography

Gilberto Valenzuela Vásquez, UNIVERSIDAD AUTONOMA DE BAJA CALIFORNIA

PROFESOR DE LA FACULTAD DE ODONTOLOGIA-MEXICALI

References

Baffone, G. M., D. Botticelli, L. Canullo, A. Scala, M. Beolchini and N. Lang. (2012). Effect of mismatching abutments on implants with wider platforms an experimental study in dogs. Clin. Oral Impl. Res., 23: 334-339.

Becerra, G. and O. Morales. (2009). Consideraciones en el Manejo de los Implantes en la Zona Estética, Revista de la Facultad de Odontología Universidad de Antioquía, 75:191-204.

Becker, J., D. Ferrari, I. Mijatovic, N. Sahm, A. Schaer and F. Schuarz. (2009). Stability of Crestal Bone Level at Platform-Switched Non-Submerged Titanium Implants: A Histomorphometrical Study in Dogs. J. Clin. Periodontal, 36:532-539.

Belic, M., V. Kusek, S. Ante, G. Juraj, R. Mirna, V. Zoran, B. Marijan and T. Romana. (2012). The influence of sex on biomechanical markers of bone turnover in dogs. Res. Vet., 93: 918-920.

Blanco, J., V. Nuñez, L. Aracil, F. Muñoz and I. Ramos. (2008). Ridge alterations following immediate implant placement in the dog: Flap versus flapless surgery. J. Clin. Periodontol, 35: 640-648.

Canullo, L., G.R. Fedele, G. Iannello and S. Jepsen. (2009). Platform switching and marginal bone level alterations: The results of a randomized-controlled trial. Clin. Oral Impl. Res., 21:115-121.

Chuang, S.K., J.J. Wei, C.W. Dowglass and T. B. Dodson. (2002). Risk factors for dental implant failure: A strategy for the analysis of clustered failure-time observations. J. Dent. Res., 81:572-577.

Cochran, D. L., D.D. Bosshardt, L. Grize, F.L. Higginbottom, A.A. Jones, R. Jung and M. Dard. (2009). Bone response to loaded implants with non-matching implant-abutment diameters in the canine mandible. J. Periodontol., 80: 609-617.

Cochran, D. L., L.P. Mau, F.L. Higginbottom, T.G. Wilson, D.D. Bosshardt, J. Schoolfield and A.A. Jones. (2012). Soft and hard tissue histologic dimensions around dental implants in the canine restored with smaller-diameter abutments: a paradigm shift in peri-implant biology. Int. J. Oral Maxillofac. Implants, 28: 494-502.

Fickl, S., O. Zuhr, H. Wachtel, C. F. J. Stappert, J.M. Stein and M.B. Hurzeler. (2008). Dimensional changes of the alveolar ridge contour after different socket preservation techniques. J. Clin. Periodontol, 35: 906-913.

Hagiwara, Y. (2009). Does platform switching really prevent crestal bone loss around implants? Japanese Dental Science Review, 51:1-10

Hartman, G.A. and D. L. Cochran. (2004). Initial bone position determines the magnitude of crestal bone remodeling. J. Periodontol., 75:572-577.

Hurzeler, M., S. Fickl, O. Zuhr and H. Wachtel. (2007). Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study. J. Oral Maxillofac. Surg., 65:33-39.

Jung, R. E., A.A. Jones, F.L. Higginbottom, T.G. Wilson, J. Schoolfield, D. Buser and D.L. Cochran. (2008). The influence of non-matching implant and abutment diameters on radiographic crestal bone levels in dogs. J. Periodontol., 79: 260-270.

Ko, C.C., W.H. Douglas, R. DeLong, M.D. Rohrer, J.Q. Swift, J.S. Hodges, K.N. An and E. L. Ritman. (2003). Effects of implant healing time on crestal bone loss of a controlled-load dental implant. J. Dent. Res., 82:585-591.

Lazzara, R.J., and S.S. Porter. (2006). Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels. Int. J. Periodontics Restorative Dent., 1: 9-17.

Matthews, M. 2014. The Impact of Gender on Dental Implant Stability assessed using Resonance Frequency: A Systematic Review. Digital Archive, University Maryland. http://hdl.handle.net/10713/4073.

Mamoru, W., H. Takuya, O. Takamichi, O. Y. Mika, O. Mai, K.Yuji, K. Norio, M. Shigeru, K. Hiromi and S. Tsukasa. (2006). Reliability of linear distance measurement for dental implant length with standardized periapical radiographs. Bull. Tokio Dent. Coll., 47: 105-115.

Messias, A., R. Reis, S. Rocha, P. Nicolau, P. Cunha and M. Lopez. (2013). New method and software prototype for automatized measurement of crestal bone levels around implants. Biodental Engineering, II, CRC press, London UK, pp 208.

NCR. Guide for the care and use of laboratory animals, The National Academies Press, 8th Edition. Available at: http://grants.nih.gov/grants/olaw/Guide-for-the-care-and-use-of-laboratory-animals.pdf. Accessed August 31, 2014.

Norma Oficial Mexicana NOM-062-ZOO-1999. Especificaciones técnicas para la producción, cuidado y uso de los animales de laboratorio; 1999. Available at: http://www.fmvz.unam.mx/fmvz/principal/archivos/062ZOO.PDF. Accessed August 31, 2014.

NRC. (2006). Nutrient Requirements of Dogs and Cats. Natl. Acad. Press,Washington, DC.

Ohlsson, C., A.E. Börjesson and L. Vandenput. (2012). Sex steroids and bone health in men. BoneKEy Reports 1, 2 http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705992/ doi:10.1038/bonekey.3

Reece, W. O. (2004). Dukes' Physiology of Domestic Animals, 12th Edition. Cornell University Press, San Diego, CA, USA.

Rodríguez, X., X. Vela, J.L. Calvo-Guirado, J. Nart and C.F. Stappert. (2011). Effect of platform switching on collagen fiber orientation and bone resorption around dental implants: a preliminary histologic animal study. Int. J. Oral Maxillofac. Implants, 27: 1116-1122.

Somborac, M. (2007). Platform switching to improve implant performance, myth or fact? Oral Health, 97: 17.

Valenzuela,V. G., R.M. Sánchez-Rubio, A. Plascencia, L.A. Soto-Cantero and I. Grau-León. 2015. El perro (Canis familiaris) como modelo animal en estudios con implantes dentales: Revisión bibliográfica actualizada. Revista ADM. 62:139-145.

Vela-Nebot, X., X. Rodriguez-Ciurana, C. Rodado-Alonso and M. Segala-Torres. (2006). benefits of an implant platform modification technique to reduce crestal bone resorption. J. of Implant Dentistry, 3:313-320.

Vignoletti, F. and I. Abrahamsson. (2012). Quality of reporting of experimental research in implant dentistry. Critical aspects in design, outcome assessment and model validation. J. Clin. Periodontol, 39: 6-27.

Weitzmann, M. N., and R. Pacifici. (2006). Estrogen deficiency and bone loss: an inflamatory tale. J. Clin. Invest., 116:1186-1194.

Downloads

Published

2015-11-27

How to Cite

Valenzuela Vásquez, G. (2015). Effect of the gonadal integrity and the gender on responses of bone crestal levels in dogs with two dental prosthetic abutment types. Nova Scientia, 7(15), 168–184. https://doi.org/10.21640/ns.v7i15.274

Issue

Section

Natural Sciences and Engineering

Metrics

Similar Articles

1 2 3 4 5 6 7 8 9 > >> 

You may also start an advanced similarity search for this article.